Specifications | |
---|
Washer tank | EX-WP10 Ex e | EX-WP10 Ex d | EX-WP10 Ex d 24-IN |
|
Certificate | |
Solenoid certification | II 2G Ex em IIC T4 Gb | II 2G Ex d IIC T6 Gb | II 2G Ex d IIC T4 Gb |
|
| II 2D Ex t ... | II 2D Ex tb ... | II 2D Ex tb ... |
|
| ... IIIC T135°C Db IP67 | ... IIC T135°C Db IP66/67 | ... IIIC T135°C Db IP66 |
|
| Tamb:-40°C to +60°C | Tamb:-60°C to +60°C | -40°C to +60°C |
|
Cable entry | Integral strain relief | 1/2" NTP | 1/2" NTP |
|
| (Cable Ø 7~8,5mm) | (Cable gland not included) | (Cable gland not included) |
|
Power consumption | |
Features | |
---|
Capacity | |
Maximum delivery height | |
Maximum operating pressure | |
Washing cycles @ 4 bar | 200 to 500 (depends on water level, camera height) |
|
Electrical | |
---|
Supply voltage | 24 Vac 50/60 Hz (Control voltage supplied by camera housing) |
|
Electrical connections | Internal terminal block for control power (solenoid) |
|
Environmental | |
---|
Operating temperature | +4 °C to +60 °C (Clear water) |
|
| -9°C to 30°C (20% Ethanol) |
|
Mechanical | |
---|
Cabinet material | |
Hose material | |
Weight | Empty: 16 kg (35 lbs); Full: 26 kg (57 lbs) |
|
Ordering information | |
---|
EX-WP10 Ex e | 10 liters pressurized water tank, 316L cabinet, Ex e (T4) |
|
EX-WP10 Ex d | 10 liters pressurized water tank, 316L cabinet, Ex d (T6) |
|
EX-WP10 Ex d-IN | 10 liters pressurized water tank, 316L cabinet, Ex d (INMETRO) |
|
EX-MK WP10 | EX-WP10 maintenance kit: filter, 10m hose, nozzle, seals and screws |
|